Ïî óìîë÷àíèþ Power supplies of devices ïåðååçäíîé the alarm system and semi-automatic blocking

Power supplies of devices ïåðååçäíîé the alarm system and semi-automatic blocking


On the sites equipped with automatic lock-out or centralised traffic control, devices ïåðååçäíîé alarm systems eat from high-voltage lines ÑÖÁ. For a food of devices of autobarriers and lamps of traffic lights for motor transport a reserve food from storage batteries is provided.

On sites where automatic lock-out or centralised traffic control is absent, devices ïåðååçäíîé alarm systems receive a food from existing transmission lines pressure 10 êÂ, substations and networks 380/220 In from which energy to consumers not below II category with a reserve from the accumulator moves.

In the absence of local sources of the electric power it is supposed to feed devices ïåðååçäíîé alarm systems from the next stations on the wires suspended on support of communication lines of Ministry of Railways.

On support of communication lines of a wire suspend with observance of following rules: pressure between wires should not exceed 250 In; wires have extreme from a field on top a traverse or on the special arms established on a top of support; at stations, in settlements and on approaches to them feeding wires have double fastening; on all extent feeding wires cross.


The battery of accumulators pressure 28 In (2 batteries on 14) ensures functioning of electric drives of barriers and reservation of fires ïåðååçäíûõ traffic lights at alternating current switching-off (fig. 261). At automatic ïåðååçäíîé alarm systems without autobarriers establish the battery of accumulators pressure 14 V.Dlja of a food of the relay and automatic lock-out schemes use the rectifier of type ÁÏØ. Division of power supplies allows to keep working capacity of automatic lock-out at damage of chains of management of an autobarrier.

At semi-automatic blocking station devices receive a food from the same sources, as automatic lock-out and centralised traffic control devices, and also from local power supplies — transmission lines pressure 10 ê and existing networks pressure 380/220 In on which carry out an electrical supply of consumers not below II category.

On fig. 262, and the scheme a litany of relay semi-automatic blocking from local ËÝÏ by pressure 10 êÂ, on fig. 262, — from a line of a longitudinal electrical supply which usually passes near to ways is shown. In mouths of stations and about premises ÄÑÏ mount power support with transformers of type the OHM which attach to a line through support with ðàçúåäèíèòåëÿìè. From power support to relay cases lay usual alarm cables.

For supply of electricity from one station on another the suspension bracket of a power chain by pressure not above 250 In on support of communication lines of Ministry of Railways with observance of the special requirements specified above is in exceptional cases supposed.


If in local networks of an alternating current fluctuations of pressure more than 10 % to a food of rectifiers and ñâåòîôîðíûõ lamps apply voltage stabilizers are observed. In devices RPB have found distribution electromagnetic stabilizers pressure of types Ñ-0,5; Ñ-0,75; Ñ-0,9.

For a reserve food of devices of semi-automatic blocking at each station provide storage batteries (from accumulators of type ÀÁÍ-72 or ÀÁÍ-80) which are calculated on work of devices during 16 ÷. Accumulators place in áàòàðåéíûõ cases together with rectifiers of type ÂÀÊ or the special zarjadno-buffer device of type ÇÁÓ-12/10, which else is in operation.

The most economic device for a food of devices of semi-automatic blocking is the regulator of a current of the MOUTH as this device has two modes of a charge — constant ïîäçàðÿä and the forced charge of the battery of accumulators the maximum current with possibility of their wide adjustment on a current and automatic switching.


Ðåäàêòîðû: Òîëÿí
Ñîçäàíî Òîëÿí, 05.09.2010 â 14:43
Ïîñëåäíåå ðåäàêòèðîâàíèå Òîëÿí, 05.09.2010 â 14:43
0 Êîììåíòàðèÿ , 1408 Ïðîñìîòðîâ
Ïîõîæèå òåìû
Òåìà Àâòîð Ðàçäåë Îòâåòîâ Ïîñëåäíåå ñîîáùåíèå
the Unified automatic control system braking action of trains (SAUT) Òîëÿí Wiki 0 05.09.2010 14:57
Power supply of devices of automatic lock-out Òîëÿí Wiki 0 05.09.2010 14:46
Power supply systems of devices STSB Òîëÿí Wiki 0 05.09.2010 14:45
Power supplies from the high-voltage wires suspended on support of a contact network Òîëÿí Wiki 0 05.09.2010 14:44
Maintenance service of devices of power supplies on stages and stations Òîëÿí Wiki 0 05.09.2010 14:42

 

Âîçìîæíî âàñ çàèíòåðåñóåò èíôîðìàöèÿ ïî ñëåäóþùèì ìåòêàì (òåìàì):
, , , , , , ,


Çäåñü ïðèñóòñòâóþò: 1 (ïîëüçîâàòåëåé: 0 , ãîñòåé: 1)
 

Âàøè ïðàâà â ðàçäåëå
Âû ìîæåòå ñîçäàâàòü íîâûå òåìû
Âû íå ìîæåòå îòâå÷àòü â òåìàõ
Âû íå ìîæåòå ïðèêðåïëÿòü âëîæåíèÿ
Âû ìîæåòå ðåäàêòèðîâàòü ñâîè ñîîáùåíèÿ

BB êîäû Âêë.
Ñìàéëû Âêë.
[IMG] êîä Âêë.
HTML êîä Âûêë.
Trackbacks are Âêë.
Pingbacks are Âêë.
Refbacks are Âûêë.



×àñîâîé ïîÿñ GMT +3, âðåìÿ: 06:16.

ßíäåêñ.Ìåòðèêà Ñïðàâî÷íèê 
ñöáèñò.ðó ñöáèñò.ðô

ÑÖÁÈÑÒ (ðàíåå íàçûâàëñÿ: Ôîðóì ÑÖÁèñòîâ - Railway Automation Forum) - êðóïíåéøèé ñàéò ðàáîòíèêîâ ëîêîìîòèâíîãî õîçÿéñòâà, äâèæåíöåâ, ýñöåáèñòîâ, ïóòåéöåâ, êîíòàêòíèêîâ, âàãîííèêîâ, ñâÿçèñòîâ, ïðîâîäíèêîâ, ðàáîòíèêîâ ÖÔÒÎ, ÈÂÖ æåëåçíûõ äîðîã, äèñòàíöèé ïîãðóçî÷íî-ðàçãðóçî÷íûõ ðàáîò è äðóãèõ æåëåçíîäîðîæíèêîâ.
Ñâÿçü ñ àäìèíèñòðàöèåé ñàéòà: admin@scbist.com
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 
Powered by vBulletin® Version 3.8.1
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
Powered by NuWiki v1.3 RC1 Copyright ©2006-2007, NuHit, LLC Ïåðåâîä: zCarot