Our 250W DC/DC converters for railway applications have a 10ms hold-up time, as well as the following features:
The operating temperature range is -40°C up to +70°C (85°C for 10min). The converters have a 10ms hold-up time, compensating small battery interrupts like short circuits opening battery lines.
Input to output is galvanically isolated. The DC/DC converters are continuously no-load and short-circuit approved. No additional components are necessary for EMC and cooling demands. The converters are available in a IP 20 housing.
The efficiency is 87% and 92% for POUT>= 0.7 Poutnom. A power fail signal pin (open collector transistor or relay) can be used for signalling overload conditions. With the enable pin the converter can be switched on or off using an external controller.
The dimensions are very compact: 240mm x 160mm x 81.5mm.